Flue Gas Oxygen Analyzer

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2021-07-07 08:51

  • Browse the number:

    355

Send an inquiries
+
Woshilong Instrument (Beijing)Co., Ltd
Contactaixin:

woshilong(Mr.)  

Email:

telephone:

+86-029-8861 0736

phone:

Arrea:

Beijing

Address:

No.9 Shuangyuan Rd, Shijingshan District hi-tech park, Beijing.

Website:

http://www.wslinstrument.com/ http://woshilong.15269268807.com/

+

Description

Flue gas oxygen analyzer is ideally suited for package boilers thanks to its long service life and low maintenance. so, it is an effective tool for the reduction of fuel and electric power consumption. Flue gas oxygen analyzer is used to analyze the oxygen content of flue gas in various industrial boilers and kilns, and optimizing air intake for boiler operation requires continuous measurement of the oxygen concentration in the flue gas. The flue gas oxygen analyzer is comprised of the detector and converter coupled together as a complete system, and the range of the oxygen sensor is 0 - 20.6%.



Application
Flue Gas Oxygen Analyzer is widely used in metallurgy, chemical, electric power, heating, environmental protection and other industries to analyze the oxygen content of flue gas in various industrial boilers and kilns, the control of pollutants in medical garbage incinerator and other fields.



Main Features
★ Easy Operation.
★ Easily replaceable zirconia element.
★ IP67 enclosure.
★ Fast response and easy to operate by functional key.


Specification

Items

Specifications

Oxygen concentration:

0.001~100 vol%

Output signal:

4~20mA DC (maximum load resistance 750Ω)

Setting range:

0~20.6 vol% (0~30% can be set)

Digital communications:

Support Modbus 232/485 and Ethernet (selectable)

Heating time:

Approx. 20 min.

Repeatability:

±0.5vol% maximum value of set range.

Zero drift:

1.5 vol% maximum value of set range (60 days)

Response time:

Response of 90% within 5 seconds. (Measured after gas is introduced from standard gas inlet and oxygen signal starts changing).

Power supply:

220±10%VAC

Installation:

Flange mounting

Limit output:

Provide settable upper and lower limit outputs (optional)

Temperature control accuracy:

0~700℃ (Floating temperature calculation)

Equipment system accuracy:

±1%F.S.

Digit display mode:

4 bit LED nixie tube display

Operation:

Menu button operation

Calibration operation:

Three parameters on-line calibration

Equipment power:

Approx. 10W (Excluding heating power)

Heating power:

50W (average), able to supply maximum 150W power output

Environmental conditions:

Ambient temperature 0~70℃, relative humidity ≤ 90%

Protection level:

IP65

Electrical interface:

M20

Explosion-proof level:

EXdII ct6 GB (only for explosion-proof type product)



Detector length

180mm\400mm\600mm\800mm\1000mm\1200mm\1500mm (customizable)

(Note: Detector length is from the detector tip to flange)


http://www.wslinstrument.com/